PDF p. 220 · 4-36
- 1.Remove the end cover, then take out the brush holder by removing its two screws.
- 2.
Measure the length of the brushes with a vernier caliper.
Alternator Brush Length:
Standard (New): 10.5 mm (0.41 in)
Service Limit: 1.5 mm (0.06 in)

- 1. VERNIER CALIPER
- 2. ALTERNATOR BRUSHES
- 3.If the brushes are less than the service limit, replace the alternator brush assembly.
Alternator Brush Inspection (MITSUBISHI)
- 1.Separate the drive-end housing from the rear housing as described on page 4-34.
- 2.Separate the rear housing from the stator/rectifier assembly by removing the four screws and the terminal nut from the rear housing (See page 4-34).
- 3.
Measure the length of the brushes with a vernier caliper.
Alternator Brush Length:
(1) Standard (New): 19 mm (0.75 in)
- (2)Service Limit: 5 mm (0.20 in)
- (2)

- 4.If the brushes are less than the service limit, replace them.

- 1. SOLDERING IRON