PDF p. 197 · 4-13
- 1.Check that there is no continuity between the + and - brush holders. If there is continuity, replace the brush holder assembly.

- 1. + BRUSH HOLDER
- 2. - BRUSH HOLDER
- 3. + BRUSH HOLDER
- 4. - BRUSH HOLDER
- 2.Insert the brush into the brush holder, and bring the brush into contact with the commutator, then attach a spring scale to the spring. Measure the spring tension at the moment the spring lifts off the brush.

- 1. SPRING SCALE
- 2. SPRING
- 3. BRUSH
Spring Tension: 15.7 - 17.7 N
(1.60 1.80 kgf, 3.56 - 4.00 lbf)
Starter Reassembly
NOTE: Use the illustration on page (See page 4-8) as reference for reassembly.
- 1.Pry back each brush spring with a screwdriver, then position the brush about halfway out of its holder, and release the spring to hold it there.

- 2.Install the armature in the housing. Next, pry back each brush spring again, and push the brush down until it seats against the commutator, then release the spring against the end of the brush.

- 1. BRUSH
- 2. BRUSH SPRING
- 3.Install the end cover on the brush holder.