PDF p. 1097 · 22-42
The performance test will help determine if the air conditioning system is operating within specifications.
NOTE:
- Use only a gauge se for refrigerant HFC-134a (R-134a).
- Use a vacuum pump adapter which is equipped with a check valve to prevent backflow of the vacuum pump oil.
If accidental system discharge occurs, ventilate work area before resuming service.
R-134a service equipment or vehicle air conditioning systems should not be pressure tested or leak tested with compressed air.
Additional health and safety information may be obtained from the refrigerant and lubrication manufacturers.
- 1.Connect the R-134a gauge set as shown.
- 2.Insert a thermometer in the centre air vent. Determine the relative humidity and air temperature.
- 3.Test conditions:
- Avoid direct sunlight
- Open hood
- Open front doors
- Set the temperature control dial to MAX COOL, the mode control dial to VENT and the recirculation control switch to RECIRCULATE.
- Turn the A/C switch on and the fan switch to MAX.
- Run the engine at 1,500 rpm (min -1)
- No driver or passengers in vehicle
- 4.
After running the air conditioning for ten minutes under the above conditions, read the delivery temperature from the thermometer in the centre air vent (the intake temperature near the blower unit behind the glove box and the high and low system pressure form the A/C gauges).
NOTE: LHD type is shown, RHD type is symmetrical.

THREE VALVE GAUGE

- 1. LOW PRESSURE VALVE
- 2. EVACUATION VALVE
- 3. HIGH PRESSURE VALVE
- 4. VACUUM PUMP
- 5. 16 mm
- 6. HIGH PRESSURE QUICK JOINT
- 7. LOW PRESSURE JOINT
- 8. 13 mm
- 9. CHECK VALVE
TWO VALVE GAUGE

- 1.LOW PRESSURE VALVE
- 2.HIGH PRESSURE VALVE
- 3.EVACUATION STOP VALVE
- 4.VACUUM PUMP
- 5.HIGH PRESSURE QUICK JOINT
- 6.16 mm
- 7.LOW PRESSURE QUICK JOINT
- 8.13 mm
- 9.CHECK VALVE
PDF p. 1098 · 22-43
- 5.To complete the charts:
- Mark the delivery temperature along the vertical line.
- Mark the intake temperature (ambient air temperature) along the bottom line.
- Draw a line straight up from the air temperature to the humidity.
- Mark a point 10% above and 10% below the humidity level.
- From each point, draw a horizontal line across the delivery temperature.
- The delivery temperature should fall between the two lines.
- Complete the low side pressure test and high side pressure test in the same way.
- Any measurements outside the line may indicate the need for further inspection
LHD Model (except KY Model):

KY Model:

RHD Model: