PDF p. 1082 · 22-27
NOTE: LHD type is shown, RHD type is symmetrical.
- 1.Remove the filter lid, then pull out the A/C filters.
- 2.Remove the self-tapping screws and the recirculation control motor.
- 3.Pull out the A/C thermostat sensor away from the evaporator fins.
- 4.Remove the self-tapping screws and the clamps, carefully separate the upper housing from the lower housing, then remove the evaporator core.
- 5.If necessary remove the expansion valve. Use a second wrench to hold the other fitting on the valve so the evaporator line won’t twist. Leave the first fitting loosely connected so you can use it to hold the valve while you loosen the second fitting.
- 6.Reassemble in the reverse order of disassembly and note the following items:
- Replace the O-rings with new ones at each fitting and apply a thin coat of refrigerant oil before installing them. Be sure to use the correct O-rings for HFC-134a (R-134a) to avoid leakage.
- Install the expansion valve capillary tube directly against the outlet line and wrap it with electrical tape.
- Reinstall the A/C thermostat sensor in its original location.
- After reassembly, make sure that the recirculation control linkage and door move smoothly before installing the recirculation control motor.
- After reassembly, make sure the recirculation control motor runs smoothly (See Page 21-13).
- Make sure that there is no air leakage.

- 1. RECIRCULATION CONTROL MOTOR, Test (See Page 21-20)
- 2. UPPER HOUSING
- 3. EVAPORATOR , Blow dirt out of fins with compressed air
- 4. ELECTRICAL TAPE, Replace
Make sure there is no foreign matter stuck between the capillary tube and outlet line - 5. EXPANSION VALVE
- 6. A/C FILTERS
- 7. LOWER HOUSING
- 8. FILTER LID
- 9. A/C THERMOSTAT, Test (See Page 22-18)
- 10. 11th fin from inlet side
- 11. 125 mm (4.92 in)