PDF p. 1048 · 21-13
- 1.Disconnect the 5P connector from the recirculation control motor.
- 2.
Connect battery power to the No. 5 terminal and ground the No. 1 and No. 2 terminals; the recirculation control motor should run smoothly. To avoid damaging the recirculation control motor, do not reverse power and ground.
RECIRCULATION CONTROL MOTOR

- 3.Disconnect the No. 1 or No. 2 terminals from ground; the recirculation control motor should stop at Fresh or Recirculate. Don’t cycle the recirculation control motor for along time.
- 4.If the recirculation control motor does not run in step 2, remove it, then check the recirculation control linkage and door for smooth movement. If they move smoothly, replace the recirculation control motor.
Replacement
NOTE: LHD type is shown, RHD is symmetrical.
- 1.Disconnect the 5P connector from the recirculation control motor. Remove the self-tapping screws and the recirculation control motor.

- 1. RECIRCULATION CONTROL MOTOR
- 2. 5P CONNECTOR
- 2.Install in the reverse order of removal. After installation, make sure the recirculation control motor runs smoothly.