Workshop manual

Inspection and Adjustment

Pump Pressure Check

Shop Manual 1999 · source: HRV_Workshop_Manual.pdf, PDF page 814 (manual page 17-19)

PDF p. 814 · 17-19

Check the fluid pressure as follows to determine whether the trouble is in the pump or gearbox.

  1. 1.
    Check the power steering fluid level (See Page 17-18) and pump belt tension (See Page 17-16).
  2. 2.
    Disconnect the supply line from the pump outlet with care so as not to spill the power steering fluid on the frame and other parts, then install the P/S joint adapter (pump) on the pump outlet.
Illustration: P/S JOINT ADAPTER (HOSE), 07RAK-S040120; SUPPLY LINE FITTING; 6 x 1.0 mm BOLT (Part of Tool); 6 mm NUT (Part of tool), 11 Nm (1.1 kgf/m, 8 lbf/ft); SHUT-OFF VALVE; 6 x 1.0 mm BOLT (Part of tool), 11 Nm (1.1 kgf/m, 8 lbf/ft); P/S JOINT ADAPTER (PUMP), 07RAK-S040110; P/S PRESSURE GAUGE, 07406-0010200; PRESSURE CONTROL VALVE
  1. 1. P/S JOINT ADAPTER (HOSE), 07RAK-S040120
  2. 2. SUPPLY LINE FITTING
  3. 3. 6 x 1.0 mm BOLT (Part of Tool)
  4. 4. 6 mm NUT (Part of tool), 11 Nm (1.1 kgf/m, 8 lbf/ft)
  5. 5. SHUT-OFF VALVE
  6. 6. 6 x 1.0 mm BOLT (Part of tool), 11 Nm (1.1 kgf/m, 8 lbf/ft)
  7. 7. P/S JOINT ADAPTER (PUMP), 07RAK-S040110
  8. 8. P/S PRESSURE GAUGE, 07406-0010200
  9. 9. PRESSURE CONTROL VALVE
  1. 3.
    Connect the P/S joint adapter (hose) to the P/S pressure gauge, then connect the supply line to the P/S joint adapter (hose).
  2. 4.
    Install the P/S pressure gauge to the P/S joint adapter (pump).
  1. 5.
    Fully open the shut-off valve.
Illustration: SHUT-OFF VALVE
  1. 1. SHUT-OFF VALVE
  1. 6.
    Fully open the pressure control valve.
  2. 7.
    Start the engine and let it idle.
  3. 8.
    Turn the steering wheel from lock-to-lock several times to warm the fluid to operating temperature.
  4. 9.

    Measure steady-state fluid pressure while the engine is idling. If the pump is in good condition, the gauge should read less than 1,500 kPa (15 kgf/cm2, 213 psi).

    If it reads high, check the outlet hose or valve body unit (see General Troubleshooting).

  5. 10.
    Close the pressure control valve, then close the shut-off valve gradually until the pressure gauge needle is stable. Read the pressure.
  1. 11.

    Immediately open the pressure control valve fully. If the pump is in good condition, the gauge should read at least 7,200-7,800 kPa (73-80 kgf/cm2, 1,040-1,140 psi).

    A low reading means pump output is too low for full assist. Repair or replace the pump.