A/T Control System - KQ and KU Models with D16W5 Engine (cont’d)

PCM CONNECTOR D (16P)

TerminalSignalDescriptionMeasuring Conditions/Terminal Voltage
Number
D1VELSecondary gear shaft speedDepending on vehicle speed: Pulsing signal
sensor signal inputWhen vehicle is stopped: Approx. 0 V
D2SOL INHInhibitor solenoid controlWith inhibitor solenoid ON: Battery voltage
With inhibitor solenoid OFF: 0 V
D3SH LSMShift control linear solenoid power
supply negative electrode
D4SH LSPShift control linear solenoid powerWith ignition switch ON (II): Pulsing signal
supply positive electrode
D5VB SOLPower supply for solenoid valvesWith ignition switch ON (II): Battery voltage
With ignition switch OFF: 0 V
D6ATP RA/T gear position switch RIn R position: 0 V
position inputIn other than R position: Approx. 10 V
D7VEL SGSecondary gear shaft speed
sensor ground
D8S2 IND indicator light controlWith S2 mode switch ON and indicator light comes
on: Battery voltage
indicator light OFF: 0 V
D9D SWD mode switch signal inputWith D mode switch ON: 0 V
With D mode switch OFF: Approx. 5 V
D10NDNDriven pulley speed sensor signalIn other than P and N position: Pulsing signal
input
D11NDRDrive pulley speed sensor signalIn other than P and N position: Pulsing signal
input
D12NDR SGDrive pulley speed sensor ground
D13S SWS1 or S2 mode switch signal inputWith S mode switch ON: 0 V
With S mode switch OFF: Approx. 5 V
D14S IND indicator light controlWith S1 mode switch ON and indicator light comes
on: Battery voltage
indicator light OFF: 0 V
D15D INDD Indicator light controlWhen ignition switch is first turned ON (II): Battery
voltage for two seconds
In D position: Battery voltage
D16NDN SGDriven pulley speed sensor ground