PDF p. 1939 · 14-8
A/T Control System - KQ and KU Models with D16W5 Engine
The PCM terminal voltage and measuring conditions are shown for the connector terminals that are related to the A/T control system. The other PCM terminal voltage and measuring conditions are described in section 11.

PCM CONNECTOR A (32P)
| Terminal | Signal | Description | Measuring Conditions/Terminal Voltage |
|---|---|---|---|
| Number | |||
| A7 | ATP D | A/T gear position switch D | In D position: 0 V |
| position input | In other than D position: Approx. 10 V | ||
| A9 | ATP NP | A/T gear position switch P and | In P and N positions: 0 V |
| N positions input | In other than P and N positions: Approx. 10 V | ||
| A10 | SCS | Timing and adjustment service | With ignition switch ON (II) and service check |
| check signal | connector open: 5 V | ||
| With ignition switch ON (II) and service check | |||
| connector connected with special tool: 0 V | |||
| A22 | ATP L | A/T gear position switch L | In L position: 0 V |
| position input | In other than L position: Approx. 10 V | ||
| A32 | STOP SW | Brake switch signal output | Brake pedal depressed: Battery voltage |
| Brake pedal released: 0 V |
PCM CONNECTOR B (25P)
| Terminal | Signal | Description | Measuring Conditions/Terminal Voltage |
|---|---|---|---|
| Number | |||
| B1 | IGP1 | Power supply circuit from main | With ignition switch ON (II): Battery voltage |
| relay | With Ignition switch OFF: 0 V | ||
| B2 | PG1 | Ground | |
| B8 | HLC LSM | PH-PL control linear solenoid | |
| power supply negative electrode | |||
| B9 | IGP2 | Power supply circuit from main | With ignition switch ON (II): Battery voltage |
| relay | With ignition switch OFF: 0 V | ||
| B10 | PG2 | Ground | |
| B17 | HLC LSP | PH-PL control linear solenoid | With ignition switch ON (II): Pulsing signal |
| power supply positive electrode | |||
| B18 | SC LSM | Start clutch control linear solenoid | |
| power supply negative electrode | |||
| B20 | LG1 | Ground | |
| B21 | VBU | Back-up power supply | Always battery voltage |
| B22 | LG2 | Ground | |
| B25 | SC LSP | Start clutch control linear solenoid | With ignition switch ON (II): Pulsing signal |
| power supply positive electrode |