Workshop manual

Countershaft Assembly

Inspection

Shop Manual 1999 · source: HRV_Workshop_Manual.pdf, PDF page 510 (manual page 13-36)

PDF p. 510 · 13-36

  1. 1.

    Inspect the gear surface and bearing surface for wear and damage, then measure the countershaft at points A, B and C.

    Standard:

Service Limit:

A: 36.000 - 36.015 mm

(1.4173 - 1.4179 in)

B: 36.984 - 37.000 mm

(1.4561 - 1.4567 in)

C: 24.987 - 25.000 mm

(0.9837 - 0.9843 in )

A: 35.95 mm (1.415 in) B: 36.93 mm (1.454 in) C: 24.94 mm (0.982 in)

Illustration: Inspect for wear and damage
  1. 1. Inspect for wear and damage
  • If any part of the countershaft is less than the service limit, replace it with a new one.
  1. 2.

    Inspect for runout.

    Standard:0.02 mm (0.0008 in) max.
    Service Limit:0.05 mm (0.002 in)

    NOTE: Support the countershaft at both ends as shown.

Illustration: Rotate two complete revolutions
  1. 1. Rotate two complete revolutions
  • If the runout exceeds the service limit, replace the countershaft with a new one.