PDF p. 322 · 10-10
NOTE: Use new O-rings when reassembling

- 1. COOLANT TEMPERATURE GAUGE SENDING UNIT, 9 Nm (0.9 kgf/m, 7 lbf/ft)
Apply liquid gasket to the threads. - 2. 6 x 1.0 mm, 11 Nm (1.1 kgf/m, 8.0 lbf/ft)
- 3. WATER OUTLET COVER.
Apply liquid gasket to mating surface. - 4. O-RING. Replace.
- 5. O-RING. Replace.
- 6. RADIATOR FAN SWITCH, 24 Nm (2.4 kgf/m, 17 lbf/ft)
- 7. 6 x 1.0 mm, 11 Nm (1.1 kgf/m, 8.0 lbf/ft)
- 8. O-RING. Replace.
- 9. CONNECTING PIPE
- 10. O-RING. Replace.
- 11. 10 x 1.25 mm, 44 Nm (4.5 kgf/m, 33 lbf/ft)
- 12. 6 x 1.0 mm, 12 Nm (1.2 kgf/m, 8.7 lbf/ft)
- 13. WATER PUMP
Inspection, (See Page 10-11) Replacement, (See Page 10-11) - 14. O-RING. Replace.
- 15. ENGINE COOLANT TEMPERATURE (ECT) SENSOR, 18 Nm (1.8 kgf/m, 13 lbf/ft)