PDF p. 321 · 10-9
Replace the thermostat if it is open at room temperature. To test a close thermostat:
- 1.Suspend the thermostat in a container of water as shown.

- 1. THERMOMETER
- 2. THERMOSTAT
- 2.Heat the water and check the temperature with a thermometer. Check the temperature at which the thermostat first opens, and at which it is fully open,
- 3.
Measure the lift height of the thermostat when it is fully open
STANDARD THERMOSTAT
Lift height: above 8 mm (0.31 in)
Starts opening: 76 - 80°C (169 - 176°F)
Fully open: 90°C (194°F)