Workshop manual

Thermostat

Testing

Shop Manual 1999 · source: HRV_Workshop_Manual.pdf, PDF page 321 (manual page 10-9)

PDF p. 321 · 10-9

Replace the thermostat if it is open at room temperature. To test a close thermostat:

  1. 1.
    Suspend the thermostat in a container of water as shown.
Illustration: THERMOMETER; THERMOSTAT
  1. 1. THERMOMETER
  2. 2. THERMOSTAT
  1. 2.
    Heat the water and check the temperature with a thermometer. Check the temperature at which the thermostat first opens, and at which it is fully open,
  2. 3.

    Measure the lift height of the thermostat when it is fully open

    STANDARD THERMOSTAT

    Lift height: above 8 mm (0.31 in)

    Starts opening: 76 - 80°C (169 - 176°F)

    Fully open: 90°C (194°F)