PDF p. 277 · 7-7
Connecting Rod End Play:
| Standard (New): | 0.15 - 0.30 mm |
| (0.006 - 0.012 in) | |
| Service Limits: | 0.40 mm (0.016 in) |

- If out-of-tolerance, install a new connecting rod.
- If still out-of-tolerance, replace the crankshaft (See Page 7-11) and (See Page 7-22).
Push the crankshaft firmly away from the dial indicator and zero the dial against the end of the crankshaft. Then pull the crankshaft firmly back towards the indicator; dial reading should not exceed service limit.

Crankshaft End Play:
| Standard (New): | 0.10 - 0.35 mm |
| (0.004 - 0.014 in) | |
| Service Limit: | 0.45 mm (0.018 in) |
- If end play is excessive, inspect the thrust washers and thrust surface on the crankshaft. Replace parts as necessary.
NOTE: Thrust washer thickness is fixed and must not be changed either by grinding or shimming.
Thrust washers are installed with grooved sides facing outwards.