Workshop manual

Troubleshooting

Symptom Chart

Shop Manual 1999 · source: HRV_Workshop_Manual.pdf, PDF page 1039 (manual page 21-4)

PDF p. 1039 · 21-4

Note the following items before troubleshooting a symptom:

  • Check the engine coolant level, and allow the engine to warm up before troubleshooting.
  • Any abnormality must be corrected before continuing the test.
  • Because of the precise measurements needed, use a digital circuit tester when testing.
  • Before performing any troubleshooting procedures check:
    • Fuse No. 56 (40 A) in the under-hood fuse/relay box, and No. 11 (7.5 A) in the under-dash fuse/relay box
    • Grounds No. G201, G401, G402
    • Cleanliness and tightness of all connectors
SymptomRemedy
Hot air flow is lowBlower motor runs, but one orPerform the procedures in the flowchart (See Page
more speeds are inoperative21-5).
Blower runs properlyCheck for the following:
♦Clogged heater duct
♦Clogged heater outlet
♦Incorrect door position
No hot air flowBlower motor does not run atPerform the procedures in the flowchart (See Page
all21-6)
Blower motor runsCheck for the following:
♦Clogged heater duct
♦Clogged heater outlet
♦Clogged heater valve
♦Faulty air mix door
♦Heater valve cable adjustment (See Page 21-20)
♦Air mix control cable adjustment (See Page
21-20)
♦Faulty cooling system thermostat (see section
10)
♦Clogged evaporator (with air conditioning)
♦Frozen evaporator (with air conditioning)
Recirculation control doors do not change between freshPerform the procedures in the flowchart (See Page
and recirculate21-9)